Published August 2015 | Version v1
Journal article

Flow characteristics of central-driven ejector with design parameters

  • 1. School of Mechanical Design Engineering, Chonnam Natona University, Gwangju (Korea, Republic of)

Description

The objective of this study is to experimentally investigate the effect of design parameter on the mass ratio of a central-driven ejector. The design parameters are the primary nozzle area and distance ratios, diffuser exit-area ratio and mixing-tube length ratio. The experimental setup was an open-loop continuous circulation system which has a movable nozzle ejector, an electric motor-pump, a water tank, a control panel and high-speed camera unit. We calculated the mass ratio using the measured primary and suction-flow rates with the experimental parameter of primary water-flow rate or pressure. The results showed that the mass ratio increased with the primary nozzle distance ratio and mixing tube length ratio, while the mass ratio decreased with the primary nozzle-area ratio and diffuser exit-area ratio

Additional details

Publishing Information

Journal Title
Transactions of the Korean Society of Mechanical Engineers. B
Journal Volume
39
Journal Issue
8
Series
31 refs, 9 figs, 2 tabs
Journal Page Range
p. 645-651
ISSN
1226-4881

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
47114546
Subject category
S42: ENGINEERING;
Descriptors DEI
COMPUTER CALCULATIONS; CONTROL; DESIGN; FLOW RATE; NOZZLES; PUMPS
Descriptors DEC
EQUIPMENT