Flow characteristics of central-driven ejector with design parameters
Creators
- 1. School of Mechanical Design Engineering, Chonnam Natona University, Gwangju (Korea, Republic of)
Description
The objective of this study is to experimentally investigate the effect of design parameter on the mass ratio of a central-driven ejector. The design parameters are the primary nozzle area and distance ratios, diffuser exit-area ratio and mixing-tube length ratio. The experimental setup was an open-loop continuous circulation system which has a movable nozzle ejector, an electric motor-pump, a water tank, a control panel and high-speed camera unit. We calculated the mass ratio using the measured primary and suction-flow rates with the experimental parameter of primary water-flow rate or pressure. The results showed that the mass ratio increased with the primary nozzle distance ratio and mixing tube length ratio, while the mass ratio decreased with the primary nozzle-area ratio and diffuser exit-area ratio
Additional details
Publishing Information
- Journal Title
- Transactions of the Korean Society of Mechanical Engineers. B
- Journal Volume
- 39
- Journal Issue
- 8
- Series
- 31 refs, 9 figs, 2 tabs
- Journal Page Range
- p. 645-651
- ISSN
- 1226-4881
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 47114546
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- COMPUTER CALCULATIONS; CONTROL; DESIGN; FLOW RATE; NOZZLES; PUMPS
- Descriptors DEC
- EQUIPMENT