Scaling of multi-pixel cryogenic detectors for imaging becomes increasingly difficult with size due to complexity of readout circuitry and cryogenic constraints (thermal load from wiring). We propose and demonstrate a new readout scheme based on a highly stable RF oscillator composed of a superconducting tunnel junction which exhibits relaxation oscillations. The oscillation frequency is almost linear with the analog bias signal over a wide operation range. The frequency signals from different detectors can be combined into one single readout line. The current noise of an optimized circuit is about 5pA/Hz, which is comparable to standard SQUID amplifiers. We show experimental data from 'stand-alone' operation as well as response to microcalorimeter X-ray signals

Additional details

Identifiers

DOI
10.1016/j.nima.2005.12.143;
arXiv
arXiv:physics/0507005v2;
PII
S0168-9002(05)02577-5;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
559
Journal Issue
2
Journal Page Range
p. 796-798