Published April 11, 2012 | Version v1
Journal article

Streamlined calibrations of the ATLAS precision muon chambers for initial LHC running

  • 1. Raymond and Beverly Sackler School of Physics and Astronomy, Tel-Aviv University, 69978 Tel Aviv (Israel)
  • 2. Department of Physics, The University of Michigan, Ann Arbor, MI 48109-1120 (United States)
  • 3. Max-Planck-Institut für Physik, Werner-Heisenberg-Institut, München (Germany)
  • 4. CERN, CH-1211 Geneva 23 (Switzerland)

Description

The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p=3% at 100 GeV and 10% at 1 TeV. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT functions depend on MDT environmental parameters and so must be appropriately calibrated for local chamber conditions. We report on the creation and application of a gas monitor system based calibration program for muon track reconstruction in the LHC startup phase.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2011.12.086

Additional details

Identifiers

DOI
10.1016/j.nima.2011.12.086;
arXiv
arXiv:1103.0797v2;
PII
S0168-9002(11)02320-5;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
671
Journal Page Range
p. 40-50
ISSN
0168-9002
CODEN
NIMAER

INIS

Optional Information

Copyright
Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.