Published 1984 | Version v1
Book

TRAC calculations of overcooling transients in PWRs for pressurized thermal shock analysis

  • 1. Los Alamos National Lab., Los Alamos, NM

Description

This paper briefly describes the overall pressurized thermal shock (PTS) program at Los Alamos with emphasis on TRAC-PF1 calculations of severe overcooling transients in pressurized water reactors (PWRs). Overcooling transients for both the Oconee-1 and Calvert Cliffs-1 nuclear plants have been performed. A summary of results for several calculations are presented for the Oconee-1 PWR along with detailed discussions of two of the most severe overcooling transients predicted (main steam-line break and turbine-bypass valve (TBV) failures). The calculations performed were plant specific in that details of both the primary and secondary sides were modeled in addition to a detailed model of the plant integrated control system (ICS). For the Oconee-1 main steam-line break transient, a minimum downcomer fluid temperature of about405 K was predicted. For the transient involving the failure of one bank of TBVs to close after initially opening following reactor and turbine trips, an extrapolated downcomer fluid temperature of about365 K was estimated. The latter temperature is at the nil-ductility temperature (NDT) limit ( about365 K) for Oconee-1

Additional details

Publishing Information

Publisher
Plenum Press.
Imprint Place
New York, NY (USA)
Imprint Title
Anticipated and abnormal plant transients in light water reactors, Vol. 1
Journal Page Range
p. 587-601.

Conference

Title
Anticipated and abnormal plant transients in light water reactors conference.
Dates
26-29 Sep 1983.
Place
Jackson, WY (USA).