Dose estimates for the 1104 m APS storage ring

Creators

Description

The estimated dose equivalent rates outside the shielded storage ring, and the estimated annual dose equivalent to members of the public due to direct radiation and skyshine from the ring, have been recalculated. The previous estimates found in LS-84 and cited in the 1987 Conceptual Design Report of the APS required revision because of changes in the ring circumference and in the proposed location of the ring with respect to the nearest site boundary. The values assumed for the neutron quality factors were also overestimated (by a factor of 2) in the previous computation, and the correct values have been used for this estimate. The methodology used to compute dose and dose rate from the storage ring is the same as that used in LS-90. The calculations assumed 80 cm thick walls of ordinary concrete (or the shielding equivalent of this) and a roof thickness of 1 meter of ordinary concrete. The circumference of the ring was increased to 1104 m, and the closest distance to the boundary was taken as 140 m. The recalculation of the skyshine component used the same methodology as that used in LS-84

Files

24050482.pdf

Files (293.8 kB)

Name Size Download all
md5:27e3d5676bb8ec4d063602f406f6bd3b
293.8 kB Preview Download
Part of:
Selected publications related to the experimental facilities of the Advanced Photon Source, 1987--1991

Additional details

Publishing Information

Imprint Title
Selected publications related to the experimental facilities of the Advanced Photon Source, 1987--1991
Imprint Pagination
741 p.
Journal Page Range
p. 9, Paper 71.
Report number
ANL/APS/LS--184