Published June 1981 | Version v1
Journal article

Duct effects on the distribution of γ-rays from a mixed radiation field in an ilmenite-concrete shield

  • 1. Atomic Energy Establishment, Cairo (Egypt)

Description

The effects of ducts on the dose distribution of γ-rays in an ilmenite-concrete shield have been investigated using a collimated beam of neutrons and γ-rays from a reactor. Measurements were performed in a homogeneous concrete medium and repeated in a medium containing cylindrical air-filled ducts having different lengths and diameters. The γ-ray doses were measured using 7LiF in Teflon matrix discs. The results show that the presence of ducts increases the γ-ray doses in the regions surrounding the ducts except for thicknesses less than 20 cm. This increase has a maximum value at positions located approx. 10 cm after the duct ends. The observed increase at peak positions depends on the duct diameters and vertical distances. (author)

Additional details

Publishing Information

Journal Title
Health Phys.
Journal Volume
40
Journal Issue
6
Series
Health Phys.
Journal Page Range
829-834
ISSN