Evaluation of dose and quality in mammography. First results of DQM programme

  • 1. Ferrara Univ. (Italy). Ist. di Fisica
  • 2. Servizio di Fisica Sanitaria, Ferrara (Italy)
  • 3. Istituto Superiore di Sanita, Rome (Italy)

Description

A programme for mammography optimisation in 31 units is carried out. The main parameters affecting dose and image quality (HVL, focal spot and exposure) are measured by means of practical devices: dosemeter, star pattern and phantoms. The dose and image-quality evaluations show that routine mammography is frequently not optimised. In fact exposure HVL, resolution and optical density values show a wide interval range; in particular, even units using the same type of X-ray apparatus and film-screen combination present very different exposure values. The authors' exposure and dose values are compared with those of 27 screening centres of the Joint ACS/NCI Breast Cancer Detection Demonstration Project, where mammography is supposed to be optimised. The lowest exposures are about the same but the maximum exposures are very different. The difference was expected; in fact, the authors' exposure data are comparable to the first results of BENT (USA), where all the mammographic units were considered, not only the screening ones. Units that are now working in optimal conditions may start a quality assurance programme to maintain these conditions; units not optimised may seek better conditions with help from the programme. (author)

Additional details

Publishing Information

Publisher
British Institute of Radiology.
Imprint Place
London (UK)
ISBN
0-905749-12-X
Imprint Title
Criteria and methods for quality assurance in medical X-ray diagnosis. Proceedings of the scientific seminar held in Udine, Italy, 17-19 April 1984
Imprint Pagination
189 p.
Journal Issue
Suppl. 18
Series
Br. J. Radiol.
Journal Page Range
p. 42-46.

Conference

Title
Scientific seminar on criteria and methods for quality assurance in medical X-ray diagnosis.
Dates
17-19 Apr 1984.
Place
Udine (Italy).

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
17082626
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; COMPARATIVE EVALUATIONS; IMAGES; ITALY; MAMMARY GLANDS; OPTIMIZATION; QUALITY ASSURANCE; RADIATION DOSES; X-RAY TUBES
Descriptors DEC
BODY; DEVELOPED COUNTRIES; DIAGNOSTIC TECHNIQUES; ELECTRON TUBES; EQUIPMENT; EUROPE; EVALUATION; GLANDS; MEDICINE; ORGANS; X-RAY EQUIPMENT

Optional Information

Secondary number(s)
EUR--9255-EN.