Published November 2019 | Version v1
Journal article

Thermal neutron capture cross sections and resonance integrals of ruthenium isotopes- 96Ru, 102Ru and 104Ru

  • 1. Department of Physics, Alagappa University, Karaikudi, Tamilnadu, 630003 (India)
  • 2. Manipal Centre for Natural Sciences, Manipal Academy of Higher Education, Manipal, Karnataka, 576104 (India)

Description

Highlights: • Thermal neutron capture cross sections and resonance integrals of 96,102,104Ru. • The cross sections are measured with reference to a55Mn monitor. • Neutrons from an Am–Be neutron source kept inside a concrete bunker is used. • 104Ru data is measured from 105Ru and 105Rh gamma emissions. - Abstract: Thermal neutron capture cross sections and resonance integrals of 96Ru, 102Ru and 104Ru are measured with reference to a 55Mn monitor. The experiments are carried out using the neutrons from an Am–Be neutron source kept inside a concrete bunker. The thermal neutron capture cross sections measured are in good agreement with the evaluations as well as with one of the recent measurements. The resonance integral of 102Ru measured in the present study is in good agreement with older measurements.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apradiso.2019.108819

Additional details

Identifiers

DOI
10.1016/j.apradiso.2019.108819;
PII
S0969804319303100;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
153
Journal Page Range
p. 108819
ISSN
0969-8043
CODEN
ARISEF

Optional Information

Notes
© 2019 Elsevier Ltd. All rights reserved.