Published 2018 | Version v1
Miscellaneous

Status of KURNS-LINAC

  • 1. Kyoto University, Institute for Integrated Radiation and Nuclear Science, Kumatori, Osaka (Japan)

Description

Operating time of KURRI-LINAC was 2,784.1 hours in 2017FY, the record high. Nuclear data was 35%, radiation measurement was 21%, radiation damage was 18%, RI manufacturing and activation analysis was 16%, coherent light source was 9%, the percentage of the operating time. Troubles were KURNS – LINAC in 2017FY, the leakage of the cooling water at No.2 klystron, the damage was minimal by experience in the past to the leakage of cooling water, and RF driver was troubled multiple times, the error of indication of the RF output power, the machine stop by reflection power over, and the error of RF output power. (author)

Part of:
Proceedings of the 15th annual meeting of Particle Accelerator Society of Japan

Additional details

Additional titles

Original title (Japanese)
京都大学複合原子力科学研究所電子線型加速器施設の現状

Publishing Information

Imprint Title
Proceedings of the 15th annual meeting of Particle Accelerator Society of Japan
Imprint Pagination
[1380 p.]
Journal Page Range
p. 1314-1316

Conference

Title
15. annual meeting of Particle Accelerator Society of Japan
Acronym
PASJ2018
Dates
7-10 Aug 2018
Place
Nagaoka, Niigata (Japan)

Optional Information

Notes
1 ref., 5 figs., 1 tab. Imprint:#7B2C#15#56DE##65E5##672C##52A0##901F##5668##5B66##4F1A##5E74##4F1A#