Published December 1992 | Version v1
Journal article

Vertical hydraulic generators experience with dynamic air gap monitoring

  • 1. Ontario Hydro, Toronto, ON (Canada)

Description

Until recently, dynamic monitoring of the rotor to stator air gap of hydraulic generators was not practical. Cost effective and reliable dyamic air gap monitoring equipment has been developed in recent years. Dynamic air gap monitoring was originally justified because of the desire of the owner to minimize the effects of catastrophic air gap failure. However, monitoring air gaps on a time basis has been shown to be beneficial by assisting in the assessment of hydraulic generator condition. The air gap monitor provides useful information on rotor and stator condition and generator vibration. The data generated by air gap monitors will assist managers in the decision process with respect to the timing and extent of required maintenance for a particular generating unit

Additional details

Publishing Information

Journal Title
IEEE Transactions on Energy Conversion
Journal Volume
7
Journal Issue
4
Journal Page Range
p. 660-668.
ISSN
0885-8969
CODEN
ITCNE4