Published March 1995 | Version v1
Report Open

Monte Carlo study of a high-sensitivity gamma-ray detection system

Description

The authors use Monte Carlo calculations to study a new design for a high-sensitivity gamma-ray detection system. The system uses an array of high-purity germanium detectors operating with an event-mode data acquisition system. The calculations show that the proposed design could produce a factor of 10 increase in the sensitivity of these measurements compared to currently employed systems

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE95015417; NTIS; US Govt. Printing Office Dep.

Files

27002541.pdf

Files (696.6 kB)

Name Size Download all
md5:60f02deeb95f138ffe24d6026d00918b
696.6 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
21 p.
Report number
UCRL-ID--120286

Optional Information

Contract/Grant/Project number
Contract W-7405-ENG-48
Funding organization
USDOE, Washington, DC (United States).