Published July 2006 | Version v1
Miscellaneous

Surface flaw evaluation by vectorized eddy current testing image

  • 1. Tohoku Univ., Inst. of Fluid Science, Sendai, Miyagi (Japan)

Description

A method of eddy current testing (ECT) data mapping for surface breaking evaluation is studied. The multicoil ECT probe utilized in this paper consists of Transmit-Receive (TR) type sensors as array elements to obtain the information on crack directions. Switching two directional scans, U- and T- modes, gives two-dimensional vector mapping as ECT images. The ECT signals of the TR type sensor also give the information on crack directions from their variation displayed on the complex number plane. Extracting a complex number component of the signals makes it possible to visualize directions of numerically simulated proximate EDM slits. (author)

Part of:
Proceedings of the 3rd annual meeting of Japan Society of Maintenology

Additional details

Additional titles

Original title (Japanese)
Nippon hozen gakkai dai-3-kai gakujutsu koenkai yoshishu

Publishing Information

Imprint Title
Proceedings of the 3rd annual meeting of Japan Society of Maintenology
Imprint Pagination
405 p.
Journal Page Range
p. 212-215

Conference

Title
3. annual meeting of Japan Society of Maintenology
Dates
6-7 Jul 2006
Place
Sendai, Miyagi (Japan)

Optional Information

Notes
7 refs., 8 figs. Imprint:Nippon hozen gakkai dai-3-kai gakujutsu koenkai yoshishu