The Thermal-hydraulic Performance Test Report for the Non-instrumented Irradiation Test Rig of Annular Fuel
Description
This report presents the results of pressure drop test, vibration test and endurance test for the non-instrumented rig using the irradiation test in HANARO of the double cooled annular fuel which were designed and fabricated by KAERI. From the out-pile thermal hydraulic tests, corresponding to the pressure drop of 200 kPa is measured to be about 9.72 kg/sec. Vibration frequency for the non-instrumented rig ranges from 5.0 to 10.7 kg/s. RMS(Root Mean Square) displacement for non-instrumented rig is less than 11.73 m, and the maximum displacement is less than 54.87m. The flow rate for endurance test were 10.5 kg/s, which was 110% of 9.72 kg/s. And the endurance test was carried out for 3 days. The test results found not to the wear and satisfied to the limits of pressure drop, flow rate, vibration and wear in the non-instrumented rig. This test was performed at the FIVPET facility
Availability note (English)
Available from INIS in electronic form; Also available from KAERI
Files
Additional details
Publishing Information
- Imprint Pagination
- 173 p.
- Report number
- KAERI/TR--3614/2008
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 40070069
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- FLOW RATE; HANARO REACTOR; MECHANICAL VIBRATIONS; PERFORMANCE TESTING; PRESSURE DROP; THERMAL HYDRAULICS
- Descriptors DEC
- ENRICHED URANIUM REACTORS; FLUID MECHANICS; HYDRAULICS; IRRADIATION REACTORS; ISOTOPE PRODUCTION REACTORS; MATERIALS TESTING REACTORS; MECHANICS; POOL TYPE REACTORS; REACTORS; RESEARCH AND TEST REACTORS; RESEARCH REACTORS; TEST FACILITIES; TEST REACTORS; TESTING; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 19 refs, 39 figs, 27 tabs