Analysis of participant factors that affect the diagnostic performance of screening mammography: A report of the alliance for breast cancer screening in Korea

  • 1. Dept. of Radiology, Konyang University Hospital, Konyang University College of Medicine, Daejeon (Korea, Republic of)
  • 2. Dept. of Radiology, Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of)

Description

To analyze participant factors that affect the diagnostic performance of screening mammography. We enrolled 128756 cases from 10 hospitals between 2005 and 2010. We analyzed recall rate, cancer detection rate (CDR) per 1000 examinations, positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), and interval cancer rate (ICR) per 1000 negative examinations according to participant factors including age, breast density, and number of visit to the same institution, and adjusted for confounding variables. Increasing age improved recall rates (27.4% in 40's, 17.5% in 50's, 11.1% in 60's, and 8.6% in 70's), CDR (2.7, 3.2, 2.0, and 2.4), PPV (1.0, 1.8, 1.8, and 2.8%), sensitivity (81.3, 88.8, 90.3, and 94.7%), specificity (72.7, 82.7, 89.0, and 91.7%), and FPR (27.3, 17.3, 11.0, and 8.4%) (p < 0.05). Higher breast density impaired recall rates (4.0% in P1, 9.0% in P2, 28.9% in P3, and 27.8% in P4), PPV (3.3, 2.3, 1.2, and 1.3%), specificity (96.1, 91.2, 71.4, and 72.5%), and FPR (3.9, 8.9, 28.6, and 27.6%) (p < 0.001). It also increased CDR (1.3, 2.1, 3.3, and 3.6) and ICR (0.2, 0.3, 0.6, and 1.6) (p < 0.05). Successive visits to the same institution improved recall rates (20.9% for one visit, 10.7% for two visits, 7.7% for more than three visits), PPV (1.6, 2.8, and 2.7%), specificity (79.4, 89.6, and 92.5%), and FPR (20.6, 10.4, and 7.5%) (p < 0.001). Young age and dense breasts negatively affected diagnostic performance in mammography screening, whereas successive visits to the same institution had a positive effect. Examinee education for successive visits to the same institution would improve the diagnostic performance

Additional details

Publishing Information

Journal Title
Korean Journal of Radiology
Journal Volume
18
Journal Issue
4
Series
28 refs, 1 fig, 4 tabs
Journal Page Range
p. 624-631
ISSN
1229-6929

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
48066605
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
DETECTION; DIAGNOSTIC TECHNIQUES; MAMMARY GLANDS; NEOPLASMS; PATIENTS; PERFORMANCE; REPUBLIC OF KOREA; SCREENING
Descriptors DEC
ASIA; BODY; DEVELOPING COUNTRIES; DISEASES; GLANDS; ORGANS