Published October 2010 | Version v1
Journal article

Vacuum ultraviolet impurity spectroscopy on the Alcator C-Mod tokamak

  • 1. Plasma Science and Fusion Center, MIT, Cambridge, Massachusetts 02139 (United States)
  • 2. Physics Division, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

Description

Vacuum ultraviolet spectroscopy is used on the Alcator C-Mod tokamak to study the physics of impurity transport and provide feedback on impurity levels to assist experimental operations. Sputtering from C-Mod's all metal (Mo+W) plasma facing components and ion cyclotron range of frequency antenna and vessel structures (sources for Ti, Fe, Cu, and Ni), the use of boronization for plasma surface conditioning and Ar, Ne, or N2 gas seeding combine to provide a wealth of spectroscopic data from low-Z to high-Z. Recently, a laser blow-off impurity injector has been added, employing CaF2 to study core and edge impurity transport. One of the primary tools used to monitor the impurities is a 2.2 m Rowland circle spectrometer utilizing a Reticon array fiber coupled to a microchannel plate. With a 600 lines/mm grating the 80<λ<1050 A range can be scanned, although only 40-100 A can be observed for a single discharge. Recently, a flat-field grating spectrometer was installed which utilizes a varied line spacing grating to image the spectrum to a soft x-ray sensitive Princeton Instruments charge-coupled device camera. Using a 2400 lines/mm grating, the 10<λ<70 A range can be scanned with 5-6 nm observed for a single discharge. A variety of results from recent experiments are shown that highlight the capability to track a wide range of impurities.

Additional details

Identifiers

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
81
Journal Issue
10
Journal Page Range
p. 10D736-10D736.4
ISSN
0034-6748
CODEN
RSINAK

Optional Information

Notes
(c) 2010 American Institute of Physics