Published November 2003 | Version v1
Journal article

Evaluation of structural parameters in semicrystalline polymer three-phase systems by small-angle X-ray scattering

  • 1. Chinese Academy of Sciences, Beijing (China). Inst. of High Energy Physics, Beijing Synchrotron Radiation Laboratory
  • 2. China Petroleum and Chemical Corporation, Beijing (China). Beijing Research Inst. of Chemical Industry

Description

The structural parameters in a semicrystalline polymer three-phase system have been evaluated using small angle X-ray scattering technique. The crystallinity and the lamellar thickness are not consistent with those in two-phase system. The analysis of some semicrystalline polymer samples indicates that the Bragg long period approaches to the sum of the correlation function long period and the thickness of the transition layer. It is also consistent with the conclusion that the interphase layers exist in semicrystalline polymers

Additional details

Publishing Information

Journal Title
High Energy Physics and Nuclear Physics
Journal Volume
27
Journal Issue
11
Journal Page Range
p. 1034-1038
ISSN
0254-3052