Published January 2016 | Version v1
Journal article

Data point selection for weighted least square fitting of cavity decay time constant

  • 1. Laboratory on Adaptive Optics, Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu 610209 (China)

Description

For the accurate extraction of cavity decay time, a selection of data points is supplemented to the weighted least square method. We derive the expected precision, accuracy and computation cost of this improved method, and examine these performances by simulation. By comparing this method with the nonlinear least square fitting (NLSF) method and the linear regression of the sum (LRS) method in derivations and simulations, we find that this method can achieve the same or even better precision, comparable accuracy, and lower computation cost. We test this method by experimental decay signals. The results are in agreement with the ones obtained from the nonlinear least square fitting method. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1674-1056/25/1/014211

Additional details

Publishing Information

Journal Title
Chinese Physics. B
Journal Volume
25
Journal Issue
1
Journal Page Range
[7 p.]
ISSN
1674-1056

INIS

Country of Publication
China
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47091522
Subject category
S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
Descriptors DEI
ACCURACY; CALCULATION METHODS; COMPARATIVE EVALUATIONS; DECAY; LEAST SQUARE FIT; NONLINEAR PROBLEMS; PERFORMANCE; SIGNALS; SIMULATION
Descriptors DEC
EVALUATION; MATHEMATICAL SOLUTIONS; MAXIMUM-LIKELIHOOD FIT; NUMERICAL SOLUTION