Published April 2016 | Version v1
Book

Experimental research on relationship between tube voltage and the thickness range of X-ray thickness measurement

  • 1. Beijing Key Laboratory of Nuclear Detection and Measurement Tsinghua University, Beijing (China)
  • 2. Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing (China)

Description

In the experiment, we first use the X-ray thickness measuring platform in our laboratory to measure a sequence of the thickness of the steel plates in a different tube voltage, then put forward the equivalent μχ method and calibration method to analyze the experimental data respectively. For different tube voltages optimal thickness range are estimated, and we finally obtain the relationship between tube voltage and the thickness range for steel plate thickness measurement. These conclusions have important guiding significance for design of high precision X-ray thickness measuring equipment. (authors)

Part of:
Progress report on nuclear science and technology in China (Vol.4). Proceedings of academic annual meeting of China Nuclear Society in 2015, No.8--Nuclear Techniques in Industry sub-volume

Additional details

Publishing Information

Publisher
China Atomic Energy Press
Imprint Place
Beijing (China)
ISBN
978-7-5022-7103-9
Imprint Title
Progress report on nuclear science and technology in China (Vol.4). Proceedings of academic annual meeting of China Nuclear Society in 2015, No.8--Nuclear Techniques in Industry sub-volume
Imprint Pagination
173 p.
Journal Page Range
p. 115-119

Conference

Title
2015 academic annual meeting of China Nuclear Society
Dates
21-24 Sep 2015
Place
Mianyang (China)

Optional Information

Notes
5 figs., 1 tab., 2 refs.