In-service inspection program of PWR containment post-tensioning system
Description
The in-service inspection procedure for the ungrouted post-tensioning system of the two identical PWR containment is prepared to conform to newly proposed USNRC Regulatory Guide 1.35, Rev. 3 and 1.35.1. The containment structure has a cylindrical wall and hemispherical dome with vertical inverted U-type tendons. The tendon in-service inspection program consists of visual inspection, tendon prestress monitoring, and material test of tendon strand and filler grease. Specifically, by constructing the strain influence line of each tendon rather than following the approach in the proposed Regulatory Guide, more reasonable values of concrete elastic shortening loss are reflected in the tolerance band for prestress monitoring
Additional details
Publishing Information
- Imprint Title
- Proceedings of the Canadian Nuclear Society international conference on containment design
- Imprint Pagination
- 227 p.
- Journal Page Range
- p. 206-212.
- Report number
- INIS-mf--12606
Conference
- Title
- International conference on containment design.
- Dates
- 17-20 Jun 1984.
- Place
- Toronto, ON (Canada).
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 21050139
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CONTAINMENT SYSTEMS; ELASTICITY; IN-SERVICE INSPECTION; PRESTRESSED CONCRETE; PWR TYPE REACTORS
- Descriptors DEC
- BUILDING MATERIALS; COMPOSITE MATERIALS; CONCRETES; CONTAINMENT; ENRICHED URANIUM REACTORS; INSPECTION; MATERIALS; MECHANICAL PROPERTIES; POWER REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS