Portable computer to reduce gamma-ray spectra for plutonium isotopic ratios

Description

In response to Task A.63 of the International Safeguards Project Office (ISPO), to upgrade measurement technology used by the International Atomic Energy Agency (IAEA), a portable data-reduction microprocessor was designed and programmed which allows in-field reduction of gamma-ray spectra and interfaces with the IAEA's multichannel analyzers - the 1000 or 2000-channel memory Silena BS27/N. This report describes the components used in assembling the microprocessor unit: hardware, software used to control the unit, and the mathematical formulation used to obtain isotopic ratios from the gamma-ray data. A simple overview is presented of the unit's operation and the results of tests on gamma-ray spectra that sought to verify the unit's operating characteristics and to determine the precision and effectiveness of the software developed for data reduction

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
36 p.
Report number
UCRL--53145

INIS

Optional Information

Secondary number(s)
ISPO--134.