Published December 2010 | Version v1
Journal article

A novel simple approach for incorporation of respiratory motion in stereotactic treatments of lung tumors

  • 1. Department of Physics and Medical Technology, VU University Medical Center, Amsterdam (Netherlands)
  • 2. Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands)

Description

Purpose: An internal target volume (ITV) is often used for incorporating tumor motion into radiotherapy planning but it overestimates the margins necessary for breathing motion. We describe a pragmatic approach using maximum- and minimum-intensity projections (MIP and Min-IP) only, for reducing ITVs in stereotactic radiotherapy by using dosimetric margins that compensate for motion-induced dose blurring. Patients and method: We studied tumor motion characteristics from 26 repeat 4DCT scans derived from 10 patients. These were used to calculate the shift in cranio-caudal direction of the 80% isodose due to dose blurring of the time-averaged dose distribution caused by respiratory motion. The dosimetric margins necessary to compensate for dose blurring were calculated relative to the ITV, which can be determined efficiently using the MIP. Peak-to-peak motion amplitude was determined using the MIP and Min-IP. A programmable respiratory motion phantom was used to investigate imaging artifacts in determining the ITV for realistic motion patterns. Dose profiles were both calculated and measured in lung- and water-equivalent tissue. Results: Using margins for the 80% dose level permitted the use of smaller target volumes relative to the use of ITV-based volumes, with (i) greater reductions seen at the end-inspiration edge than at expiration side due to asymmetric breathing motion patterns and (ii) a linear relationship seen with breathing amplitude. The average reduction of the ITV at a 95% confidence level is given by 0.2 x App - 1.3 mm at expiration side, where App is the peak-to-peak breathing amplitude, and 0.3 x App - 2.2 mm at inspiration side. Dosimetric margins did not differ significantly between water-equivalent and lung tissue for 80% isodose. Conclusion: A simple margin recipe for breathing motion linear with breathing amplitude can be used to calculate the ITV reductions achievable for stereotactic radiotherapy of lung tumors.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radonc.2010.06.007

Additional details

Identifiers

DOI
10.1016/j.radonc.2010.06.007;
PII
S0167-8140(10)00391-9;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
97
Journal Issue
3
Journal Page Range
p. 443-448
ISSN
0167-8140
CODEN
RAONDT

INIS

Country of Publication
Ireland
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42081109
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
LUNGS; MOTION; NEOPLASMS; RADIATION DOSE DISTRIBUTIONS; RADIOTHERAPY; RESPIRATION
Descriptors DEC
BODY; DISEASES; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESPIRATORY SYSTEM; THERAPY

Optional Information

Copyright
Copyright (c) 2010 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.