Optimal MR protocol for hepatic hemangiomas. Comparison of conventional spin-echo sequences with T2-weighted turbo spin-echo and serial gradient-echo (FLASH) sequences with gadolinium enhancement
Creators
- 1. Dept. of Diagnostic Radiology, Seoul National Coll. of Medicine (Korea, Republic of)
Description
Purpose: To compare conventional spin-echo (SE) sequences with T2-weighted turbo SE and serial gadolinium-enhanced T1-weighted FLASH sequences in the detection and characterization of hepatic hemangiomas, and to describe the enhancement characteristics of the lesions on dynamic MR imaging. Material and Methods: Forthy-two patients with 66 hemangiomas were studied at 1.0 T or 1.5 T by using conventional SE sequences (T1-weighted, T2-weighted, and heavily T2-weighted), T2-weighted turbo SE sequences, and breath-hold T1-weighted FLASH sequences acquired before, immediately after, and 1, 2, 3, 5, and 10 min after injection of a bolus of gadopentetate dimeglumine. Images were quantitatively analyzed for lesion-to-liver contrast-to-noise (C/N) ratios, and qualitatively analyzed for lesion conspicuity. The enhancement pattern and the rapidity of enhancement were analyzed in small (<15 mm), medium (15-39 mm), and large (>39 mm) hemangiomas. Results: In T2-weighted images, T2-weighted turbo SE and heavily T2-weighted SE images had higher C/N ratios than T2-weighted SE images (p=0.003). Lesion conspicuity was not significantly different in these 3 sequences (p=0.307). In T1-weighted images, T1-weighted FLASH images had higher C/N (p<0.001) and also better lesion conspicuity (p<0.001) than T1-weighted SE images. Immediate uniform enhancement was seen in 43% of small hemangiomas (9 of 21 lesions), and persistent central hypointensity was seen in 73% of large hemanigomas (11 of 15 lesions). Rapid enhancement was seen in 62% of small hemangiomas (13 of 21 lesions) and in 31% of medium or large hemangiomas (14 of 45 lesions). (orig.)
Additional details
Publishing Information
- Journal Title
- Acta Radiologica
- Journal Volume
- 38
- Journal Issue
- 4,pt.1
- Journal Page Range
- p. 565-571.
- ISSN
- 0284-1851
- CODEN
- ACRAE3
INIS
- Country of Publication
- Sweden
- Country of Input or Organization
- Sweden
- INIS RN
- 28067935
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ANGIOMAS; DIAGNOSTIC TECHNIQUES; IMAGES; LIVER CELLS; NEOPLASMS; NMR IMAGING; SPIN ECHO; TECHNOLOGY ASSESSMENT
- Descriptors DEC