Optimum FIR filter for sampled signals in presence of jitter

  • 1. Istituto Nazionale di Fisica Nucleare, Pavia (Italy)

Description

The requirements of the integrated readout electronics for calorimetry at high luminosity hadron colliders pose new challenges both to hardware design and to the performance of signal processing algorithms. Both aspects have been treated in detail by the FERMI(RD16) collaboration, from which this work has been motivated. The estimation of the amplitude of sampled signals is usually performed with a digital FIR filter, or with a more sophisticated non linear digital filter using FIR filters as building blocks. In presence of significant signal phase jitter with respect to the clock, the phase dependence of the filter output can be a major source of error. This is especially true for measurements of large amplitudes for which the effect of electronic noise becomes negligible. This paper reports on the determination of digital FIR filters that optimize the signal over noise ratio due to known jitter distributions for different filter lengths. As the presence of electronic noise is neglected, the results are mainly relevant for measurements of large signals. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
373
Journal Issue
1
Journal Page Range
p. 93-96.
ISSN
0168-9002
CODEN
NIMAER

INIS

Country of Publication
Netherlands
Country of Input or Organization
Netherlands
INIS RN
27048916
Subject category
S99: GENERAL AND MISCELLANEOUS;
Descriptors DEI
ALGORITHMS; AMPLITUDES; CALORIMETRY; DATA PROCESSING; DIGITAL FILTERS; ERRORS; NONLINEAR PROBLEMS; OPTIMIZATION; PULSE TECHNIQUES; PULSES; READOUT SYSTEMS; SIGNAL-TO-NOISE RATIO