Mark III LOCA-related hydrodynamic load definition. Generic technical activity B-10. Final report
Description
This report, prepared by the staff of the Office of Nuclear Reactor Regulation and its consultants at the Brookhaven National Laboratory, provides a discussion of LOCA-related suppression pool hydrodynamic loads in boiling water reactor (BWR) facilities with the Mark III pressure-suppression containment design. Its issuance completes NRC Generic Technical Activity B-10, Behavior of BWR Mark III Containment. On the basis of certain large-scale tests conducted between 1973 and 1979, the General Electric Company developed LOCA-related hydrodynamic load definitions for use in the design of the standard Mark III containment. The staff and its consultants have reviewed these load definitions and their bases and conclude that, with a few specified changes, the proposed load definitions provide conservative loading conditions. The staff approved acceptance criteria for LOCA-related hydrodynamic loads are provided in an appendix
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A05/MF A01 - GPO* $4.75 as TI85900064.
Files
Additional details
Publishing Information
- Imprint Pagination
- 100 p.
- Report number
- NUREG--0978-F
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 16031282
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- BWR TYPE REACTORS; CONTAINMENT; HYDRODYNAMICS; LOSS OF COOLANT; PRESSURE SUPPRESSION; TRANSIENTS
- Descriptors DEC
- ACCIDENTS; ENRICHED URANIUM REACTORS; FLUID MECHANICS; MECHANICS; POWER REACTORS; REACTOR ACCIDENTS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS