Published July 2002 | Version v1
Journal article

Seismic qualification of the air cleaning units for nuclear power plant Ulchin 5 and 6

  • 1. LG Cable, Anyang (Korea, Republic of)
  • 2. Sunchon National Univ., Suncheon (Korea, Republic of)

Description

Seismic qualification of the Air Cleaning Units for nuclear plant Ulchin 5 and 6 has been performed with the guideline of ASME Section III and IEEE 3444 code. By using the structural and geometrical similarity analysis, the three models to be analyzed are condensed into a single model and, at the same time, the excitation forces and other operating loads for each model are encompassed with respect to different loading conditions. As the fundamental frequencies of the structure are found to be less than 33Hz, which is the upper frequency limit of the seismic load, response spectrum analysis using ANSYS is performed in order to combine the modal stresses within the frequency limit. In order to confirm the structural and electric stability of the major components, modal analysis theory is adopted to derive the required response spectrum at the component locations. As the all combined stresses obtained from the above procedures are less than allowable stresses and no mechanical or electrical failures are found from the seismic testing, the authors confirm the safety of the nuclear equipments Air Cleaning Units studied in this paper

Additional details

Publishing Information

Journal Title
Transactions of the Korean Society of Mechanical Engineers. A
Journal Volume
26
Journal Issue
7
Series
13 refs, 16 figs, 5 tabs
Journal Page Range
p. 1376-1383
ISSN
1226-4873

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
33067913
Subject category
S42: ENGINEERING;
Descriptors DEI
AIR CLEANING; FREQUENCY ANALYSIS; NUCLEAR POWER PLANTS; SEISMIC DETECTION; SPECTRA; STABILITY
Descriptors DEC
CLEANING; DETECTION; NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS