Published July 2012 | Version v1
Journal article

Porous glass electroosmotic pumps reduced bubble generation using reversible redox solutions

  • 1. Sogang Univ., Seoul (Korea, Republic of)

Description

This paper presents the performance of a porous glass electroosmotic pump using an iodide/triiodide aqueous solution. The porous glass electroosmotic pump is characterized in terms of the flow rate and voltage. The flow rate and voltage increases linearly with current. A point where the voltage significantly increases is observed owing to an excess in redox capacity. The transition time monotonously decreases with current. The normalized flow rate (flow rate per membrane surface area) is used to compare previous results with results obtained in this study. The normalized flow rate of porous glass frits is three times higher than that of Nafion 117

Additional details

Publishing Information

Journal Title
Transactions of the Korean Society of Mechanical Engineers. B
Journal Volume
36
Journal Issue
7
Series
20 refs, 7 figs
Journal Page Range
p. 753-757
ISSN
1226-4881

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
44072556
Subject category
S42: ENGINEERING;
Descriptors DEI
AQUEOUS SOLUTIONS; BUBBLES; FLOW RATE; PERFORMANCE; PUMPS
Descriptors DEC
DISPERSIONS; EQUIPMENT; HOMOGENEOUS MIXTURES; MIXTURES; SOLUTIONS