Dual-gated volumetric modulated arc therapy
- 1. Department of Radiation Oncology, Stanford University, Stanford, CA (United States)
- 2. School of Health Sciences, Purdue University, West Lafayette, IN (United States)
- 3. Purdue School of Engineering and Technology, Indiana University School of Informatics, IUPUI, Indianapolis, IN (United States)
Description
Gated Volumetric Modulated Arc Therapy (VMAT) is an emerging radiation therapy modality for treatment of tumors affected by respiratory motion. However, gating significantly prolongs the treatment time, as delivery is only activated during a single respiratory phase. To enhance the efficiency of gated VMAT delivery, a novel dual-gated VMAT (DG-VMAT) technique, in which delivery is executed at both exhale and inhale phases in a given arc rotation, is developed and experimentally evaluated. Arc delivery at two phases is realized by sequentially interleaving control points consisting of MUs, MLC sequences, and angles of VMAT plans generated at the exhale and inhale phases. Dual-gated delivery is initiated when a respiration gating signal enters the exhale window; when the exhale delivery concludes, the beam turns off and the gantry rolls back to the starting position for the inhale window. The process is then repeated until both inhale and exhale arcs are fully delivered. DG-VMAT plan delivery accuracy was assessed using a pinpoint chamber and diode array phantom undergoing programmed motion. DG-VMAT delivery was experimentally implemented through custom XML scripting in Varian's TrueBeam™ STx Developer Mode. Relative to single gated delivery at exhale, the treatment time was improved by 95.5% for a sinusoidal breathing pattern. The pinpoint chamber dose measurement agreed with the calculated dose within 0.7%. For the DG-VMAT delivery, 97.5% of the diode array measurements passed the 3%/3 mm gamma criterion. The feasibility of DG-VMAT delivery scheme has been experimentally demonstrated for the first time. By leveraging the stability and natural pauses that occur at end-inspiration and end-exhalation, DG-VMAT provides a practical method for enhancing gated delivery efficiency by up to a factor of two
Availability note (English)
Available from http://dx.doi.org/10.1186/1748-717X-9-209; Available from http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4261568Additional details
Identifiers
Publishing Information
- Journal Title
- Radiation Oncology (Online)
- Journal Volume
- 9
- Journal Page Range
- vp.
- ISSN
- 1748-717X
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47066193
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- DELIVERY; EXHALATION; RADIATION DOSES; RADIOTHERAPY
- Descriptors DEC
- CLEARANCE; DOSES; EXCRETION; MEDICINE; NUCLEAR MEDICINE; RADIOLOGY; THERAPY
Optional Information
- Copyright
- Copyright (c) Fahimian et al.
- Notes
- PMCID: PMC4261568; PMID: 25255839; PUBLISHER-ID: 1193; OAI: oai:pubmedcentral.nih.gov:4261568; licensee BioMed Central Ltd. 2014