Published 1993 | Version v1
Report

Loss of precision in resonant beam position monitors due to finite Q

  • 1. CERN, Genvea (Switzerland)

Description

The performance of resonant beam position monitors is limited in part by the presence of a symmetrical (common mode) excitation of the cavity. Due to finite Q, a centred beam will give a non-zero output at the observation frequency. This interference is analysed and general expressions are given for the electrical and magnetic spectral densities, split into the wanted resonant term and the open-quotes broad-bandclose quotes unwanted signal, for a cavity with arbitrary shape. This analysis is particularly relevant to beam position monitor studies for the CERN linear collider (CLIC), where very precise measurement of transverse beam position is required. It is shown that a common mode position error of under 1μm is obtainable from a high Q 33 GHz pill-box, even prior to the use of any external difference-taking elements

Additional details

Publishing Information

Imprint Title
Proceedings of the 1993 Particle Accelerator Conference: Volume 3
Imprint Pagination
970 p.
Journal Page Range
p. 2346-2348.
Report number
DOE/ER/40779--1-Vol.3

Conference

Title
international particle accelerator conference.
Acronym
PAC '93
Dates
17-20 May 1993.
Place
Washington, DC (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
26025444
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
BEAM MONITORS; BEAM POSITION; OSCILLATION MODES; PERFORMANCE; Q-VALUE; RESONANCE
Descriptors DEC
ENERGY; MEASURING INSTRUMENTS; MONITORS