Published 2024 | Version v1
Book

Preliminary diagnostic reference levels for computed tomography examinations in Uttarakhand, India

  • 1. Department of Medical Physics, Himalayan Institute of Medical Sciences, Swami Rama Himalayan University, Jolly Grant, Dehradun – 248 016 (India)

Description

Computed tomography (CT) is an important imaging modality that is widely employed for patient diagnosis across the globe. However, its increased usage has made it a significant contributor to population exposure from diagnostic X-rays. To optimize radiation exposure in CT, it is recommended to determine diagnostic reference levels (DRLs) in terms of the two measurable dose metrics, namely, computed tomography dose index (CTDI) and dose-length product (DLP). The present study was aimed to carry out an extensive survey of CT doses in Uttarakhand state of India. Radiation dose measurements were conducted on 48 CT scanners for three routine examinations (head, thorax, and abdomen) to obtain CT dose data for establishing preliminary DRLs for CT. Dose measurements were performed using an ion chamber positioned within designated grooves into two concentric water-equivalent head and body phantoms. Significant discrepancies in doses were observed, primarily due to variations in CT scanner types and scanning parameters. The DRL values were found to be lower than the corresponding European DRLs for all types of CT examinations. Additionally, the dose values for conventional, single, and double-slice scanners were relatively smaller compared to those of multi slice CT scanners. The estimated values of effective doses for the considered examination were also found below the corresponding results reported in literature. The findings highlight the need for ongoing monitoring and implementation of DRLs in CT practices to optimize patient doses. (author)

Part of:
Proceedings of the fifth national conference on radiation awareness and detection in natural environment: abstract book

Additional details

Publishing Information

Publisher
Graphic Era Deemed to be University
Imprint Place
Dehradun (India)
Imprint Pagination
146 p.
Journal Page Range
p. 110

Conference

Title
5. national conference on radiation awareness and detection in natural environment
Acronym
RADNET-V
Dates
7-9 Oct 2024
Place
Dehradun (India)

INIS

Country of Publication
India
Country of Input or Organization
India
INIS RN
56001620
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COMPUTERIZED TOMOGRAPHY; DOSE RATES; EFFECTIVE RADIATION DOSES; PERSONNEL DOSIMETRY; PERSONNEL MONITORING
Descriptors DEC
DIAGNOSTIC TECHNIQUES; DOSES; DOSIMETRY; MONITORING; RADIATION DOSES; RADIATION MONITORING; TOMOGRAPHY

Optional Information

Notes
Article ID: P-57