Development of X-ray CT test apparatus for post irradiation examination. Post irradiation examination of irradiated 'JOYO' subassembly

  • 1. Japan Nuclear Cycle Development Inst., Oarai, Ibaraki (Japan). Oarai Engineering Center

Description

The X-ray CT (Computerized Tomography) test apparatus has been developed as a non-destructive examination device for examining the internal condition of subassembly (Bundle Duct Interaction, etc) and for reflecting to soundness confirmation and fuel-life estimation, and installed in the extension facility of Fuel Monitoring Facility. In this report, the influence of gamma ray on CT image and post-irradiation examination faculties were evaluated in the case of fuel subassembly (PFD512) irradiated in 'JOYO'. (1) The CT and scanogram image of PFD512 (subassembly average burn up; 58,600 MWd/t) became possible to observe the internal state (arrangement of internal pins, distribution of the central void and crack) of irradiated subassembly. And it is not influenced by gamma rays emitted from an irradiated subassembly. (2) If the image ability of normal scan mode is evaluated in method defined by ASTM, the dimensional measurement accuracy is ±0.33 mm in the case of JOYO' subassembly. (author)

Availability note (English)

Available from INIS in electronic form

Files

31043243.pdf

Files (1.4 MB)

Name Size Download all
md5:5fb133f0e2b1db51708952c6a86f48fc
1.4 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
66 p.
Report number
JNC-TN--9410-99-020

Optional Information

Notes
6 refs., 25 figs., 4 tabs.