Published 1996 | Version v1
Book

Large CSC chamber for the PHENIX muon detector with ultra thin cathode foils

  • 1. Los Alamos National Lab., NM (United States)

Description

The muon tracking system for the PHENIX detector at RMC uses cathode strip chambers(CSC) for the tracking detectors. These detectors must provide 100 μm resolution per measurement plane to give satisfactory mass resolution of the vector mesons. The intermediate station (station 2) must have a very small radiation length, and large acceptance. We have prototyped a full scale CSC chamber to test the use of 25 micron metalized mylar foils for the cathode strips at station 2. The full scale prototype detector is a trapezoid, 2.3 meters high and 2.3 meters wide. The foil and wire planes are mounted on thin 3.2 mm thick by 7.5 cm wide laminated frames and the tension of the planes is maintained by the two large 7.5cm wide x 3.0 cm thick aluminum support frames. The total radiation length of the active region is 8.5 x 10-4

Additional details

Publishing Information

Publisher
IEEE Service Center.
Imprint Place
Piscataway, NJ (United States)
Imprint Title
1996 IEEE nuclear science symposium - conference record. Volumes 1, 2 and 3
Imprint Pagination
2138 p.
Journal Page Range
p. 274-278.

Conference

Title
Institute of Electrical and Electronic Engineers (IEEE) nuclear science symposium and medical imaging conference.
Dates
2-9 Nov 1996.
Place
Anaheim, CA (United States).

Optional Information

Secondary number(s)
CONF-961123--.