Published January 2004 | Version v1
Journal article

Electron paramagnetic resonance dosimetric response of Li2SO4 : CaSO4 mixture in mixed radiation environment - a case study

  • 1. Radiation Safety Systems Division, Bhabha Atomic Research Centre, Mumbai (India)
  • 2. Radiochemistry Division, Bhabha Atomic Research Centre, Mumbai (India)

Description

A new Electron Paramagnetic Resonance (EPR) dosimetry system based on the EPR response of 2:1 mixture of Li2SO4: CaSO4 is presented. The dose response of the material irradiated with 60Co gamma radiation was found to be linear in the range 3 Gy to 52 kGy having signal repeatability within ± 1 %. The dose response of the material irradiated in a mixed field of neutron flux of 3 x 1012 n-cm-2s-l also showed linearity in response for 5 minute to 45 minutes of irradiation. Some of the EPR signal parameters investigated include: peak to peak signal intensity vs neutron fluence, Δt = 5 min to 60 min, peak to peak signal intensity vs microwave power. Signal fading and repeatability, batch homogeneity and zero dose response. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection and Environment
Journal Volume
27
Journal Issue
1-4
Journal Page Range
p. 43-47
CODEN
RPREFM

Optional Information

Notes
17 refs., 7 figs.