Published June 2017
| Version v1
Journal article
Analysis of measurement uncertainty for dent depth of nuclear equipment
Creators
- 1. China Nuclear Power Design Engineering Co. Ltd., Shenzhen (China)
Description
The measurement methods for dent depth on nuclear mechanical component were discussed during the installation and service of pressurized water reactors. The origins for the measurement errors in the welding inspection by calipers and moulding film were analyzed. Based on the measurement data from dents on the steam generator plate, the evaluation methods for the measurement uncertainty of the above two techniques were provided, and the uncertainty component was analyzed. The combined standard uncertainty was calculated. The calculated result indicated that the uncertainty of two methods come from the random uncertainty component of repeated measurement and system uncertainty component of system correction imperfection. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Power Engineering
- Journal Volume
- 38
- Journal Issue
- 3
- Journal Page Range
- p. 81-84
- ISSN
- 0258-0926
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 52062061
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CORRECTIONS; DEFECTS; DEPTH; EQUIPMENT; ERRORS; EVALUATION; FILMS; INSPECTION; INSTALLATION; MOLDING; ORIGIN; PLATES; PWR TYPE REACTORS; RANDOMNESS; STANDARDS; STEAM GENERATORS; WELDING
- Descriptors DEC
- BOILERS; DIMENSIONS; ENRICHED URANIUM REACTORS; FABRICATION; JOINING; POWER REACTORS; REACTORS; THERMAL REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 2 figs., 3 tabs., 6 refs.