Published June 2017 | Version v1
Journal article

Analysis of measurement uncertainty for dent depth of nuclear equipment

  • 1. China Nuclear Power Design Engineering Co. Ltd., Shenzhen (China)

Description

The measurement methods for dent depth on nuclear mechanical component were discussed during the installation and service of pressurized water reactors. The origins for the measurement errors in the welding inspection by calipers and moulding film were analyzed. Based on the measurement data from dents on the steam generator plate, the evaluation methods for the measurement uncertainty of the above two techniques were provided, and the uncertainty component was analyzed. The combined standard uncertainty was calculated. The calculated result indicated that the uncertainty of two methods come from the random uncertainty component of repeated measurement and system uncertainty component of system correction imperfection. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Power Engineering
Journal Volume
38
Journal Issue
3
Journal Page Range
p. 81-84
ISSN
0258-0926

Optional Information

Notes
2 figs., 3 tabs., 6 refs.