Published November 2002 | Version v1
Book

Test and monitoring of safety system in Dhruva reactor

  • 1. Reactor Control Div., Bhabha Atomic Research Centre, Mumbai (India)

Description

Full text: Emergency cooling system (ECS) ensures operation of auxiliary cooling pumps on a failure of main coolant supply in Dhruva reactor. ECS removes decay heat from the core. The finite impulse testing (FIT) of emergency cooling system (ECS) is a system to check the healthiness of ECS. The functions of FIT are to force finite impulse on certain combination of inputs on the ECS channel and check its predicted output; declare fault if any, and specify the fault. The testing has to be done without causing an actual ECS

Part of:
First national conference on nuclear reactor technology

Additional details

Publishing Information

Publisher
Bhabha Atomic Research Centre
Imprint Place
Mumbai (India)
Imprint Title
First national conference on nuclear reactor technology
Imprint Pagination
421 p.
Journal Page Range
p. 314

Conference

Title
1. nuclear reactor safety
Acronym
NRT-1
Dates
25-27 Nov 2002
Place
Mumbai (India)

Optional Information