Design of a computer-controlled multileaf collimator for advanced electron radiotherapy
- 1. Department of Radiotherapy and Radio-Oncology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany)
- 2. 3D Line Medical Systems, Schwarzenbruck (Germany)
- 3. 3D Line Medical Systems, Milan (Italy)
Description
A multileaf collimator for electrons (eMLC) has been designed that fulfils the technical requirements for providing advanced irradiation techniques with electrons. In the present work, the basic design parameters of leaf material, leaf height, leaf width and number of leaves as well as leaf overtravel and leaf shape were determined such that an eMLC with motorized leaves can be manufactured by a company specialized in MLC technology. For this purpose, a manually driven eMLC with variable source-to-collimator distance (SCD) was used to evaluate the chosen leaf specification and investigate the impact of the SCD on the off-axis dose distribution. In order to select the final SCD of the eMLC, a compromise had to be found between maximum field size, minimum beam penumbra and necessary distance between eMLC and isocentre to eliminate patient realignments during gantry rotation. As a result, the eMLC is placed according to the target position at 72 and 84 cm SCD, respectively. This feature will be achieved by interchangeable distance holders. At these SCDs, the corresponding maximum field sizes at 100 cm source-to-isocentre distance are 20 x 20 cm and 17 x 17 cm, respectively. Finally, the off-axis dose distribution at the maximum opening of the eMLC was improved by fine-tuning the settings of the accelerator jaws and introducing trimmer bars above the eMLC. Following this optimization, a prototype eMLC consisting of 2 x 24 computer-controlled brass leaves is manufactured by 3D Line Medical Systems
Availability note (English)
Available online at http://stacks.iop.org/0031-9155/51/5987/pmb6_23_003.pdf or at the Web site for the journal Physics in Medicine and Biology (ISSN 1361-6560) http://www.iop.org/Additional details
Identifiers
- URL
- http://stacks.iop.org/0031-9155/51/5987/pmb6_23_003.pdf; http://www.iop.org/;
- DOI
- 10.1088/0031-9155/51/23/003;
- PII
- S0031-9155(06)21821-9;
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 51
- Journal Issue
- 23
- Journal Page Range
- p. 5987-6003
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 38008634
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCELERATORS; BEAMS; COLLIMATORS; IRRADIATION; OPTIMIZATION; PATIENTS; RADIATION DOSE DISTRIBUTIONS; RADIOTHERAPY; SPECIFICATIONS; TUNING
- Descriptors DEC
- MEDICINE; NUCLEAR MEDICINE; RADIOLOGY; THERAPY