Published October 2005 | Version v1
Report

Post-test calculation of primary-to-secondary leak on the PSB-VVER experimental facility. Test 4. Rev. 0

Description

A break on the hot collector of steam generator No. 4 was simulated. PSB/VVER is a 1:300 mockup of the VVER-1000 reactor. The break size was equivalent to 100 mm at a VVER-1000 reactor. The ATHLET MOD2.0 CYCLE B best-estimate computer code was used for the calculations

Availability note (English)

Available (also in the electronic format as a PDF facsimile) from Nuclear Research Institute Rez, 250 68 Rez, Czech Republic; e-mail contact: ret@nri.cz, ric@nri.cz

Additional details

Additional titles

Original title (Czech)
Post-test vypocet uniku chladiva z primarniho do sekundarniho okruhu u experimentalniho zarizeni PSB-VVER. Test 4. Rev. 0

Publishing Information

Imprint Pagination
66 p.
Report number
UJV--12305-T

Optional Information

Notes
6 tabs., 75 figs., 8 refs.