Performance evaluation of the QC-6PLUS quality control system in terms of photons and electrons absorbed doses to water
Description
The quality of the treatment in radiotherapy depends on the necessary knowledge of the liberated dose in the tumor and of several other physical parameters and dosimetric that characterize the profile of the radiation field. Worrying about the reliability of some commercial equipment that aim at determining the main parameters of a radiation field in a practical way for daily checks in an institution with radiotherapy service, in this work a study of the performance of the quality assurance system, QC6-Plus manufactured by PTW-Freiburg for daily checks, was developed, in order to assure the use of this equipment with larger reliability level in the routine of quality assurance of the hospitals as well as to make possible its use in the Program of Regulatory Inspections of the Services of Radiotherapy of the Country accomplished by IRD/CNEN. The found results indicate that the system QC6-Plus is perfectly adapted and practical for relative measures of daily and weekly control of the main parameters of clinical beans in agreement with reference values recommended in TECDOC 1151. However for measurements of absolute dose it should not be used because, for beams of electrons the system does not present the necessary characteristics to execute this measure type in agreement with the reference protocol, TRS 398, and for photons of energy 15 MV presented a deviation in relation to the conventional method of absolute dosimetry of 7,7%, that it is a lot above the expected in agreement with TRS 398. (author)
Availability note (English)
Available from INIS in electronic formFiles
40028919.pdf
Files
(998.4 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:c66af2af50db99cbe05d6131ae3ce815
|
998.4 kB | Preview Download |
Additional details
Additional titles
- Original title (Portuguese)
- Avaliacao do desempenho do sistema de controle da qualidade QC-6Plus em termos de dose absorvida na agua para fotons e eletrons
Publishing Information
- Imprint Pagination
- 80 p.
- Report number
- INIS-BR--4787
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 40028919
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Thesis
- Descriptors DEI
- ABSOLUTE COUNTING; CALIBRATION STANDARDS; COBALT 60; COMPUTERIZED CONTROL SYSTEMS; DEPTH DOSE DISTRIBUTIONS; ELECTROMETERS; ELECTRON BEAMS; HOSPITALS; IMAGES; IONIZATION CHAMBERS; IRRADIATION DEVICES; LINEAR ACCELERATORS; MEASURING INSTRUMENTS; MEDICAL SURVEILLANCE; PHANTOMS; PHOTON BEAMS; QUALITY ASSURANCE; RADIATION DOSES; RADIOTHERAPY; RECOMMENDATIONS
- Descriptors DEC
- ACCELERATORS; BEAMS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BUILDINGS; COBALT ISOTOPES; CONTROL SYSTEMS; COUNTING TECHNIQUES; DOSES; ELECTRIC MEASURING INSTRUMENTS; ELECTRICAL EQUIPMENT; EQUIPMENT; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LEPTON BEAMS; MEASURING INSTRUMENTS; MEDICAL ESTABLISHMENTS; MEDICINE; MINUTES LIVING RADIOISOTOPES; MOCKUP; NUCLEAR MEDICINE; NUCLEI; ODD-ODD NUCLEI; ON-LINE CONTROL SYSTEMS; ON-LINE SYSTEMS; PARTICLE BEAMS; RADIATION DETECTORS; RADIATION DOSE DISTRIBUTIONS; RADIOISOTOPES; RADIOLOGY; SPATIAL DOSE DISTRIBUTIONS; STANDARDS; STRUCTURAL MODELS; THERAPY; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- 23 refs., 16 figs., 24 tabs.