Numerical evaluation for a five-sensor probe method to measure the interfacial area concentration under the bubble fluctuation condition
Description
Interfacial area concentration is an important parameter in the two phase flow models. Currently, two types of probe methods, double-sensor and four-sensor, are widely used to measure the interfacial area concentration. In this study, a configuration of five-sensor probe sensor tips and a measuring method for the interfacial area concentration by using the probe are proposed to improve the performance of the previous probe methods. The five-sensor probe method proposed in this study is essentially based on the four-sensor probe method but improves it by adapting one more sensor. The passing types of the interfaces through the sensors are categorized into four and independent methods are applied to the interfaces belonging to each category. This method has an advantage such that a more systematic approach for missing bubbles can be made when compared with the classical four sensor probe method. To verify the applicability of the five-sensor probe method, numerical tests are performed with consideration of the bubble lateral movement. The effects of bubble size and intensity of the bubble lateral motion on the measurement of the interfacial area concentration are also investigated. The bubble parameters related to the bubble fluctuation and interface geometry are determined by the Monte Carlo approach
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Seoul (Korea, Republic of)
- Imprint Title
- Proceedings of the tenth international topical meeting on nuclear reactor thermal hydraulics
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [11 p.]
Conference
- Title
- NURETH-10
- Dates
- 5-11 Oct 2003
- Place
- Seoul (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 36067305
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- BUBBLES; EVALUATION; FLUCTUATIONS; MONTE CARLO METHOD; PERFORMANCE; PROBES; TWO-PHASE FLOW
- Descriptors DEC
- CALCULATION METHODS; FLUID FLOW; VARIATIONS
Optional Information
- Notes
- 10 refs, 15 figs