Breast lesions on MRI in mass and non-mass enhancement: Kaiser score and modified Kaiser score + for readers of variable experience

  • 1. Department of Radiological Sciences, University of California, Irvine, CA (United States)
  • 2. Department of Radiology, First Affiliated Hospital of Wenzhou Medical University, Wenzhou (China)
  • 3. First Affiliated Hospital of Wenzhou Medical University, Wenzhou (China)
  • 4. Department of Medical Imaging and Radiological Sciences, Kaohsiung Medical University, Kaohsiung, Taiwan (China)
  • 5. Key Laboratory of Intelligent Medical Imaging of Wenzhou, First Affiliated Hospital of Wenzhou Medical University, Wenzhou (China)

Description

To compare the diagnostic performance of three readers using BI-RADS and Kaiser score (KS) based on mass and non-mass enhancement (NME) lesions. A total of 630 lesions, 393 malignant and 237 benign, 458 mass and 172 NME, were analyzed. Three radiologists with 3 years, 6 years, and 13 years of experience made diagnoses. 596 cases had diffusion-weighted imaging, and the apparent diffusion coefficient (ADC) was measured. For lesions with ADC > 1.4 × 103 mm2/s, the KS was reduced by 4 as the modified KS +, and the benefit was assessed. When using BI-RADS, AUC was 0.878, 0.915, and 0.941 for mass, and 0.771, 0.838, 0.902 for NME for Reader-1, 2, and 3, respectively, better for mass than for NME. The diagnostic accuracy of KS was improved compared to BI-RADS for less experienced readers. For Reader-1, AUC was increased from 0.878 to 0.916 for mass (p = 0.005) and from 0.771 to 0.822 for NME (p = 0.124). Based on the cut-off value of BI-RADS ≥ 4B and KS ≥ 5 as malignant, the sensitivity of KS by Readers-1 and -2 was significantly higher for both Mass and NME. When ADC was considered to change to modified KS +, the AUC and the accuracy for all three readers were improved, showing higher specificity with slightly degraded sensitivity. The benefit of KS compared to BI-RADS was most noticeable for the less experienced readers in improving sensitivity. Compared to KS, KS + can improve specificity for all three readers. For NME, the KS and KS + criteria need to be further improved. KS provides an intuitive method for diagnosing lesions on breast MRI. BI-RADS and KS face greater difficulties in evaluating NME compared to mass lesions. Adding ADC to the KS can improve specificity with slightly degraded sensitivity.

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00330-024-10922-1

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology (Internet)
Journal Volume
35
Journal Issue
1
Journal Page Range
p. 140-150
ISSN
1432-1084
CODEN
EURAE3