Published April 20, 1983 | Version v1
Journal article

Removal of impurity ions from a plasma during Alfven-wave absorption

Description

Experiments in the R-0 stellarator show that the radial transport of impurities can be effectively modified during Alfven-wave heating. The concentration of impurity ions decreases when the frequency of the rf field is equal to the cyclotron frequency of these ions

Additional details

Publishing Information

Journal Title
JETP Lett. (Engl. Transl.)
Journal Volume
37
Journal Issue
8
Series
JETP Lett. (Engl. Transl.).
Journal Page Range
451-454
ISSN
0021-3640

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
15045088
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
ALFVEN WAVES; CYCLOTRON FREQUENCY; IMPURITIES; PLASMA HEATING; STELLARATORS
Descriptors DEC
CLOSED PLASMA DEVICES; HEATING; HYDROMAGNETIC WAVES; THERMONUCLEAR DEVICES

Optional Information

Notes
Cover-to-cover translation of Pis'ma v Zhurnal Ehksperimental'noj i Teoreticheskoj Fiziki (USSR).