Performance of X-ray equipment used for conventional radiographic examinations of children
Creators
- 1. Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN/MG), Belo Horizonte, MG (Brazil)
- 2. Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear
Description
The performance of X-ray equipment that are used for conventional X-ray examinations of children in four hospitals of Belo Horizonte, Brazil, was evaluated. The methodology proposed by the Brazilian authority for radiation protection in diagnostic radiology was adopted. The performance tests were carried out in six X-ray machines and they consisted of measurements and determination of the X-ray tube output, linearity and constancy of radiation output, accuracy and reproducibility of the exposure time and tube potential, half-value layer (HVL), light field / X-ray field alignment and accuracy of the X-ray field indicator. It was observed that only one hospital had the suitable equipment for X-ray examinations of children. Results showed that all six equipment of the four hospitals presented unsatisfactory performance in some quality control tests. Only for some combinations of the exposure parameters, generally employed in pediatric X-ray examinations, some equipment complied with the authority requirements. (author)
Availability note (English)
Available from INIS in electronic formFiles
40106330.pdf
Files
(223.0 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:0e2eb10de79ffdc6b519f54dec0975f1
|
223.0 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- [7 p.]
- Report number
- INIS-BR--6304
Conference
- Title
- International nuclear atlantic conference. Innovations in nuclear technology for a sustainable future; 16. Brazilian national meeting on reactor physics and thermal hydraulics; 9. Brazilian national meeting on nuclear applications; 1. Meeting on nuclear industry
- Acronym
- INAC 2009
- Dates
- 27 Sep - 2 Oct 2009
- Place
- Rio de Janeiro, RJ (Brazil)
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 40106330
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference, Numerical Data
- Descriptors DEI
- ACCURACY; BIOMEDICAL RADIOGRAPHY; CHILDREN; EXPERIMENTAL DATA; HOSPITALS; PERFORMANCE; QUALITY ASSURANCE; QUALITY CONTROL; RADIATION PROTECTION; X-RAY EQUIPMENT
- Descriptors DEC
- AGE GROUPS; ANIMALS; BUILDINGS; CONTROL; DATA; DIAGNOSTIC TECHNIQUES; EQUIPMENT; INFORMATION; MAMMALS; MAN; MEDICAL ESTABLISHMENTS; MEDICINE; NUCLEAR MEDICINE; NUMERICAL DATA; PRIMATES; RADIOLOGY; VERTEBRATES
Optional Information
- Notes
- 4 refs., 6 figs., 3 tabs. Published only in CD-Rom. Code: e02_529_fullpaper.pdf