Published July 1996 | Version v1
Journal article

Vapotron as heat sink for flat high-conductivity unidirectional carbon-fiber-composite tiles

  • 1. Joint European Torus Joint Undertaking, Abingdon (United Kingdom)
  • 2. Japan Atomic Energy Research Inst., Ibaraki (Japan)

Description

Two vapotrons from the Joint European Torus (JET) actively cooled divertor design have been fitted by the Japan Atomic Energy Research Institute with unidirectional high-conductivity carbon-fiber-composite tiles and have been tested in the JET Neutral Beam Test Bed. The test section showed excellent uniformity and accepted power densities up to 30 MW/m2 for equilibrium pulses. The surface temperature was 1100 degree C at 20 MW/m2. One tile detached at a power density of 25MW/m2. A total of just under 300 pulses at power densities mostly between 20 and 30 MW/m2 have been fired onto the test sections without additional failure. The hydraulic parameters were as follows: water inlet temperature, 15 to 20 degree C; average water pressure in the component, 0.4 and 0.69 MPa; flow velocity, 6.9 and 7.5 m/s. 8 refs., 15 figs., 1 tab

Additional details

Publishing Information

Journal Title
Fusion Technology
Journal Volume
29
Journal Issue
4
Journal Page Range
p. 571-583.
ISSN
0748-1896
CODEN
FUSTE8

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
28003770
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY; S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
BEAM PROFILES; CARBON FIBERS; COMPOSITE MATERIALS; DIVERTORS; HEAT FLUX; HEAT SINKS; PRESSURE DROP; REACTOR COMPONENTS; SURFACES; TESTING
Descriptors DEC
FIBERS; MATERIALS