Published December 2004 | Version v1
Journal article

Observation of antiproton beams and nonneutral plasmas

  • 1. CERN, Geneva (Switzerland)
  • 2. TRIUMF Canadian National Lab. for Nuclear and Particle Physics, Vancouver, BC (Canada)
  • 3. RIKEN, Wako, Saitama (Japan)

Description

Diagnostics of antiproton beams and nonneutral plasmas are described in this chapter. Parallel plate secondary electron emission detectors are used to non-destructively observe the beam position and intensity without loss. Plastic scintillation tracking detectors are useful in determining the position of annihilations of antiprotons in the trap. Three-dimensional imaging of antiprotons in a Penning trap is discussed. The unique capability of antimatter particle imaging has allowed the observation of the spatial distribution of particle loss in a trap. Radial loss is localized to small spots, strongly breaking the azimuthal symmetry expected for an ideal trap. By observing electrostatic eigen-modes of nonneutral plasmas trapped in the Multi-ring electrode trap, the non-destructive measurement of plasma parameters is performed. (author)

Additional details

Publishing Information

Journal Title
Purazuma, Kaku Yugo Gakkai-Shi
Journal Volume
80
Journal Issue
12
Journal Page Range
p. 1022-1026
ISSN
0918-7928

Optional Information

Notes
15 refs., 8 figs.