Published August 1, 2005 | Version v1
Report

Calibration of the surface array of the Pierre Auger Observatory

Description

The ground array of the Pierre Auger Observatory will consist of 1600 water Cherenkov detectors, deployed over 3000 km2. The remoteness and large number of detectors required a simple, automatic remote calibration procedure. The primary physics calibration is based on the average charge deposited by a vertical and central throughgoing muon, determined with good precision at the detector via a novel rate-based technique and later with higher precision via charge histograms. This value is named the vertical-equivalent muon (VEM). The VEM and the other parameters needed to maintain this calibration over the full energy range and to assess the quality of the detector are measured every minute. This allows an accurate determination of the energy deposited in each detector when an atmospheric cosmic ray shower occurs

Availability note (English)

Available from PURL: https://www.osti.gov/servlets/purl/15020246-5lnR5x/

Additional details

Publishing Information

Imprint Pagination
4 p.
Report number
FERMILAB-CONF--05-281-E-TD

Conference

Title
29. International Cosmic Ray Conference (ICRC 2005)
Dates
3-11 Aug 2005
Place
Pune (India)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
36113070
Subject category
S72: PHYSICS OF ELEMENTARY PARTICLES AND FIELDS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ACCURACY; CALIBRATION; CHERENKOV COUNTERS; ENERGY RANGE; MUONS; WATER
Descriptors DEC
ELEMENTARY PARTICLES; FERMIONS; HYDROGEN COMPOUNDS; LEPTONS; MEASURING INSTRUMENTS; OXYGEN COMPOUNDS; RADIATION DETECTORS

Optional Information

Contract/Grant/Project number
AC--02-76CH03000
Funding organization