Three-dimensional thermal analysis for a conceptual high-level waste repository in welded tuff

Description

A near-field, three-dimensional, thermal-conduction analysis was done for 2.16-kW high-level waste canisters emplaced in welded tuff. Initial thermal loadings of 75 and 100 kW/acre were investigated. The conductivities used were 2.4 W/m.0C for the saturated tuff and 1.55 W/m.0C for the dry tuff. The tuff was modeled as always saturated and with boiling of the interstitial water. Calculations were done with the ADINAT finite-element code and associated pre- and post processor codes. For the 100-kW/acre initial loading, boiling of the interstitial water, and an initial temperature of 350C, the maximum canister temperature was 2960C

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01 as DE82015503.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
30 p.
Report number
SAND--81-0215