High dose rate (HDR) and low dose rate (LDR) interstitial irradiation (IRT) of the rat spinal cord
Description
Purpose: To describe a newly developed technique to study radiation tolerance of rat spinal cord to continuous interstitial irradiation (IRT) at different dose rates. Material and methods: Two parallel catheters are inserted just laterally on each side of the vertebral bodies from the level of Th10 to L4. These catheters are afterloaded with two 192Ir wires of 4 cm length each (activity 1-2.3 mCi/cm) for the low dose rate (LDR) IRT or connected to the HDR micro-Selectron for the high dose rate (HDR) IRT. Spinal cord target volume is located at the level of Th12-L2. Due to the rapid dose fall-off around the implanted sources, a dose inhomogeneity across the spinal cord thickness is obtained in the dorso-ventral direction. Using the 100% reference dose (rate) at the ventral side of the spinal cord to prescribe the dose, experiments have been carried out to obtain complete dose response curves at average dose rates of 0.49, 0.96 and 120 Gy/h. Paralysis of the hind-legs after 5-6 months and histopathological examination of the spinal cord of each irradiated rat are used as experimental endpoints. Results: The histopathological damage seen after irradiation is clearly reflected the inhomogeneous dose distribution around the implanted catheters, with the damage predominantly located in the dorsal tract of the cord or dorsal roots. With each reduction in average dose rate, spinal cord radiation tolerance is significantly increased. When the dose is prescribed at the 100% reference dose rate, the ED50 (induction of paresis in 50% of the animals) for the HDR-IRT is 17.3 Gy. If the average dose rate is reduced from 120 Gy/h to 0.96 or 0.49 Gy/h, a 2.9- or 4.7-fold increase in the ED50 values to 50.3 Gy and 80.9 Gy is observed; for the dose prescribed at the 150% reference dose rate (dorsal side of cord) ED50 values are 26.0, 75.5 and 121.4 Gy, respectively. Using different types of analysis and in dependence of the dose prescription and reference dose rate, the α/β ratio varies between 1.46 (0.06-3.08 CL) and 2.17 Gy (0.08-4.61). The half time of repair during continuous irradiation is 1.76 h (1.33-2.64), while no indication is found for a biphasic pattern of the kinetics of repair. Conclusion: The implantation technique in our study has shown to be a reliable model to compare the effectiveness of HDR- and LDR-interstitial continuous irradiation at different dose rates
Additional details
Identifiers
- PII
- S0167814096018622;
Publishing Information
- Journal Title
- Radiotherapy and Oncology
- Journal Volume
- 42
- Journal Issue
- 1
- Journal Page Range
- p. 59-67
- ISSN
- 0167-8140
- CODEN
- RAONDT
INIS
- Country of Publication
- Ireland
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 34044724
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- INTERNAL IRRADIATION; IRIDIUM 192; LOW DOSE IRRADIATION; RADIATION INJURIES; RADIATION SOURCE IMPLANTS; RADIOSENSITIVITY; RATS; SPINAL CORD
- Descriptors DEC
- ANIMALS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BIOLOGICAL EFFECTS; BIOLOGICAL RADIATION EFFECTS; CENTRAL NERVOUS SYSTEM; DAYS LIVING RADIOISOTOPES; DISEASES; ELECTRON CAPTURE RADIOISOTOPES; HEAVY NUCLEI; IMPLANTS; INJURIES; INTERNAL CONVERSION RADIOISOTOPES; IRIDIUM ISOTOPES; IRRADIATION; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MAMMALS; MINUTES LIVING RADIOISOTOPES; NERVOUS SYSTEM; NUCLEI; ODD-ODD NUCLEI; RADIATION EFFECTS; RADIATION SOURCES; RADIOISOTOPES; RODENTS; VERTEBRATES; YEARS LIVING RADIOISOTOPES
Optional Information
- Copyright
- Copyright (c) 1997 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.