The Numerical Sensitivity Study of Cold Leg Top Slot Break for ATLAS

  • 1. KEPCO, Daejeon (Korea, Republic of)

Description

In this study, cold leg top slot break calculations are performed by RELAP5/MOD3.3 Patch04 for the ATLAS test which is the scaled down experimental facility for the APR1400. The test condition for base case is selected as 0.1016 m (4 in.) based on the break size of the APR1400. In addition, sensitivity studies about break size, break distance from vessel, and pressurizer location are performed until the initiation of simultaneous injection of 2.5 hours. The loop seal reformation occurs early, and the duration of final loop seal reformation is longer as the break is close to vessel. Nonetheless, PCT increased by loop seal reformation is not identified since core uncovery does not occur. In this study, it is confirmed through RELAP5 simulation of the ATLAS test that cold leg top slot break for the APR1400 is not a safety issue in perspective of the loop seal reformation.

Part of:
Proceedings of the KNS 2016 Spring Meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Daejeon (Korea, Republic of)
Imprint Title
Proceedings of the KNS 2016 spring meeting
Imprint Pagination
[1 CD-ROM]
Journal Page Range
[4 p.]

Conference

Title
2016 spring meeting of the KNS
Dates
11-13 May 2016
Place
Jeju (Korea, Republic of)

INIS

Optional Information

Notes
2 refs, 8 figs, 1 tab