Published June 2016 | Version v1
Journal article

Temperature dependence of alpha-induced scintillation in the 1,1,4,4-tetraphenyl-1,3-butadiene wavelength shifter

  • 1. Department of Physics, Engineering Physics and Astronomy, Queen's University, Kingston, Ontario, Canada, K7L 3N6 (Canada)

Description

Liquid noble based particle detectors often use the organic wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene (TPB) which shifts UV scintillation light to the visible regime, facilitating its detection, but which also can scintillate on its own. Dark matter searches based on this type of detector commonly rely on pulse-shape discrimination (PSD) for background mitigation. Alpha-induced scintillation therefore represents a possible background source in dark matter searches. The timing characteristics of this scintillation determine whether this background can be mitigated through PSD. We have therefore characterized the pulse shape and light yield of alpha induced TPB scintillation at temperatures ranging from 300 K down to 4 K, with special attention given to liquid noble gas temperatures. We find that the pulse shapes and light yield depend strongly on temperature. In addition, the significant contribution of long time constants above ∼50 K provides an avenue for discrimination between alpha decay events in TPB and nuclear-recoil events in noble liquid detectors.

Availability note (English)

Available from http://dx.doi.org/10.1088/1748-0221/11/06/P06003

Additional details

Publishing Information

Journal Title
Journal of Instrumentation
Journal Volume
11
Journal Issue
06
Journal Page Range
p. P06003
ISSN
1748-0221