A cylindrical xenon ionization chamber detector for high resolution, room temperature gamma radiation spectroscopy

  • 1. Virginia Commonwealth Univ., Richmond, VA (United States). Dept. of Chem. Eng.
  • 2. Space and Naval Warfare Systems Center, San Diego, CA 92152 (United States)
  • 3. Department of AMES, University of California at San Diego, La Jolla, CA 92093 (United States)

Description

A 0.75 l gridded cylindrical ionization chamber gamma radiation detector using highly purified xenon near the critical point as the detection medium is described. The detector operates at room temperature with a noise subtracted intrinsic energy resolution of 1.8% at 662 keV. The detector design and performance variables are discussed in comparison to previous planar and cylindrical xenon detectors. (orig.)