Published June 1989 | Version v1
Report

Design of the protection crowbar for the LHCD klystrons in Jet

  • 1. Commission of the European Communities Abingdon, (UK). JET Joint Undertaking
  • 2. SIEMENS A.G. Erlangen (Germany, F.R.)

Description

The JET Lower Hybrid Current Drive Generator (LHCD) will consist of 24 Klystrons. The system is expected to be fully operational in 1990. It will be composed of six modules of four klystrons each and of two klystrons for the testing of the LHCD component. Two klystron modules will be ready for operation with the JET machine in early 1989. In order to protect the klystrons in case of arcing or overvoltage, crowbars near the klystrons are foreseen. For this purpose ignitrons as opposed to thyristors were chosen. The design of the crowbar for the LHCD takes into account the past experience obtained from operation of the Neutral Beam protection crowbars and follows a different approach for the ignitron triggering and the anode/cathode temperature control

Part of:
Jet Joint Undertaking. Vol. 2

Additional details

Publishing Information

Imprint Title
Jet Joint Undertaking. Vol. 2
Imprint Pagination
648 p.
Journal Page Range
p. A360-A364.
Report number
EUR--12323

Conference

Title
15. Symposium on Fusion Technology (SOFT).
Dates
19-23 Sep 1988.
Place
Utrecht (Netherlands).

Optional Information

Secondary number(s)
EUR-JET-PR--6.